Container steam plant ready for shipment to customer
We offer fully equipped and autonomous container steam plants, ready for installation on a trailer or directly on a truck frame. We dispose growing fleet of such a systems for rental.

Container steam plants - individual execution

Container steam plants are based on Clayton steam generators. Thanks to its small footprint it is possible to enclose whole boiler room installation in standard 20 or 40 ft container.

Mobility of such a solution makes huge advantage in each industry sector where high quality steam is needed for distributed technological processes. Principal examples can be trenchless pipe repairs or oil periodical storage tanks cleaning. As well the container boiler can operate as stationary. It is the best option in case, there is no more place in a factory for steam plant installation.

Up from company beginnings we projected and assembled numerous container steam plants of summary steam power of over 25 MW. Our experience gained for the last two decades helps us meet needs of every - even the most demanding customer.

Container steam plant rental

For the customers who are in need of immediate or periodical demand of steam we offer rental of a container mobile steam plant. An example can be a construction site, where steam is necessary only in first part of a project or a fruit processing plant where demand for significant amount of steam comes in every harvest season. Steam rental can be also a perfect solution in case of planned extension of your boiler room or undesired breakdowns and repairs.

In order to meet expectations of the market, we introduced in 1995 container steam plant rental program. Gradually extending our offer, today we have three fully equipped and autonomous container steam plants, designed to suit each business.

Container steam plants IWT 1, IWT 2

Equipment list:

  • Clayton steam generator SEOG-304
  • water softener BWT Rodomat 28 SE
  • chemical dosing system BWT
  • hotwell tank
  • Clayton booster pump
  • steam manifold
  • blowdown tank

Technical specification

Net heat output kW 2943
Equivalent output kg/h 4695
Design pressure bar 10
Design temperature °C 190
Gas consumption at maximum steam output Nm3/h 350
Oil consumption at maximum steam output l/h 320
Nominal supply voltage V 400 3~
Nominal supply frequency Hz 50
Electric power kW 24
Dimensions
length mm 6000
width mm 2900
height mm 3500

Container steam plant IWT 3

Equipment list:

  • steam generator Clayton EO-40-1
  • water softener BWT Eurosoft E91DWZ
  • chemical dosing system BWT Medomat 60
  • hotwell tank, vertical
  • oil tanks 2 x 1,5 m3
  • Clayton booster pump
  • blowdown tank

Technical specification

Net heat output kW 392
Equivalent output kg/h 626
Design pressure bar 10
Design temperature °C 190
Gas consumption at maximum steam output Nm3/h 42
Oil consumption at maximum steam output l/h 44
Nominal supply voltage V 400 3~
Nominal supply frequency Hz 50
Electric power kW 3,9
Dimensions
length mm 6200
width mm 2300
height mm 2500

Photos of steam generators IWT 1, 2, 3